Troubleshooting and Maintenance Manual for LightPulse Adapters
Page 9
Configuration Checklist
Verify recommended driver, firmware, and boot versions from your storage and system 
provider.
 Many providers qualify specific adapter models, driver and firmware releases that they 
support. Using qualified provider solutions will ensure you have a supported SAN configuration. 
Verify releases for storage and system providers that have a page on the Emulex Web 
site. 
If the provider is not listed, verify any preferred driver releases. If the provider does not 
have a preference, Emulex recommends the latest driver and firmware releases. Latest releases 
ensure the latest enhancements and bug fixes.
Review the Prerequisites and Compatibility sections in the driver manual. This ensures 
that you meet the minimal requirements for each installed driver. The driver manual lists 
supported firmware versions and OS releases. The driver manual may also contain other 
information regarding tested SAN environments. 
Verify preferred settings with your storage and system providers. Many providers require 
particular Emulex driver settings for communicating with their storage. Verify with your providers 
any configuration changes they recommend. When performing configuration changes to the 
drivers and utilities, be sure to have the providers verify that the change will not affect 
communications to your storage devices. 
Review procedures and settings in the driver and utilities manuals. Each OS has its own 
system of configuring drivers. In some cases, the tools to configure the Emulex driver are the 
same between OSs. On some OSs, only manual configuration through text files is available. 
Review the manual to ensure familiarity with the process, prior to making configuration changes. 
Emulex utilities have few configurations that can be changed. See the driver and utilities 
manuals for configuration changes available for the utility you are using. 
Driver parameters can be different between OSs. Be familiar with the parameters to 
make the configuration process easier, especially if multiple OSs are used. 
Some settings are dynamic and take effect immediately, while others require the OS to 
be rebooted. Note which settings you are changing and when a reboot is necessary. 
Assume that you need server downtime to perform changes. Changing parameters on a 
production machine is not recommended unless downtime has been scheduled.   
Verify driver settings are set correctly. Defaults are optimized for normal operation and 
Emulex recommends default settings in most cases. By default, all Emulex drivers perform 
automatic mapping of FC nodes to target IDs (SCSI IDs). If SAN changes occur, the target 
mapping may not stay consistent for each FC node between reboots of the OS. Use Persistent 
binding or target mapping to insure target IDs do not change between server reboots.
Configure the driver using instructions in the driver and utilities manuals. Manual links are 
available on the same page as the driver download. The HBAnyware utility manual has 
parameter lists with minimum and maximum values for each setting. If a parameter can be 
changed with tools other than the HBAnyware utility, parameter information is in the HBAnyware 
utility and the driver manuals. Review this parameter list before you perform changes to insure 
values are not out of range or invalid. If changes require a reboot, schedule downtime for 
performing the changes.  
Note: For SAN disk drives (storage arrays) on Windows, persistent binding is not 
necessary. Windows uses the drive signature on each drive to determine the correct 
drive letter. Persistent binding is necessary for SAN tape devices on Windows.
Caution: 
Do not make configuration changes to a production server unless downtime 
has been scheduled. These changes can cause issues with access to the 
SAN storage, thereby causing unexpected server downtime.