Emulex Adapters User Manual

Page of 23
 
Troubleshooting and Maintenance Manual for LightPulse Adapters
Page 5
Isolating the Problem
Once the problem is observed, determine where the problem originates. Eliminate problem sources on a 
coarse level, is the problem in the SAN or in the server? Determining this reduces the size and scope 
of the troubleshooting effort. If the SAN can be eliminated, only the server and its components need to 
be examined. This topic discusses common problems related to the SAN and the server.
SAN Components
SAN-related problems can include the switch, storage and cabling. 
Cables
Bad cables. Noise generates many CRC or other invalid data on the FC link. This trans-
lates into slower performance on disks and failed backups on tapes. 
Old cables. 4Gb/s FC cannot run as far as 2Gb/s FC with the same cable. 
Switch
Improper zoning. This causes devices to be improperly discovered and the SAN does 
not recover from disturbances.
Link problems. These include wrong speed, wrong topology or no link at all.
Storage
Improperly configured storage systems. Emulex has determined that this is the number 
one cause of SAN performance problems. Examples of improperly configured storage 
systems include not enough spindles dedicated to the busiest Logical Units (LUNs) or 
too many hosts talking to a particular storage port.
Server Components
Server problems can include the adapter and its firmware, adapter device drivers, adapter management 
software, OS SCSI stack drivers and path management software. 
Adapter firmware 
If this is not qualified by the storage and systems providers, unpredictable behaviors 
could result.
Outdated firmware. Outdated firmware can cause link problems (wrong speed, wrong 
topology or no link at all). Tape backups can fail when using the FCP-2 Sequence Level 
Recovery feature which is enabled automatically if the tape system supports it.
Unsupported dual-channel adapters. Some dual-channel adapters are not supported by 
certain systems. 
Bad adapter. If the system stops responding, install the adapter in another server to 
determine if the problem is the adapter.
Adapter device drivers 
Unqualified driver version. The version must be qualified by the storage and systems 
providers. A version can be installed and supported by the storage or system provider, 
but provider compatibility specifies an older driver version is required for a particular 
configuration.