3
Configuring a CLARiiON Boot Device
3-21
Configuring an EMC Boot Device
register the HBA connection. If you will later install PowerPath or 
ATF, be sure to select the corresponding parameters during the 
registration procedure. Refer to your EMC ControlCenter 
Navisphere Management software, ATF, or PowerPath 
documentation for detailed instructions.
6. Press 
ESC
 until you exit the 
Fast!UTIL
 Options menu. You do not 
need to save any changes if prompted.
7. Reboot the server.
When the QLogic BIOS banner (shown in step 1) appears, press 
CTRL–Q
.
Different HBA models may display different banners. Be sure to select 
CTRL-Q for the HBA you wish to configure.
8. After 
Fast!UTIL
 loads, the display depends on whether there are 
multiple QLogic HBAs installed:
• If there is only one QLogic HBA, the 
Fast!UTIL
 Options 
menu appears.
• If there are multiple QLogic HBAs, a list of addresses occupies 
by those HBAs appears. Use the arrow keys to select the 
desired HBA; then press 
ENTER
. The 
Fast!UTIL
 Options menu 
appears.
9. Select Configuration Settings from the menu.
10. Select Selectable Boot Settings from the Configuration Settings 
menu. 
Select the first Boot Port Name entry, and in the Device window 
select the CLARiiON port WWN from which you want to boot.
After you select the WWN, if there is more than one LUN 
detected, select the boot LUN number from the next window.
11. When all parameters are set correctly, press 
ESC
 to return to the 
Fast!UTIL
 Options menu; then select Save Changes to save the 
changes you made to the current adapter.
12. Press 
ESC
 to exit the 
Fast!UTIL
 Options menu.
13. Reboot the server.
What Next?
Install Windows as described in the next section.