EMC QLA22xx User Manual

Page of 78
3
3-26
Configuring an EMC Boot Device
Assigning a 
Permanent Boot 
Drive Letter for 
Windows NT
If you have installed failover software into a Windows NT 4.0 server, 
it is good practice to hard-code the boot volume letter so that it does 
not change when rebooting after a LUN trespass. This can be done by 
using the following procedure (from MSKB Q153619):
1. Reassign all drive letters (including C: and the CD-ROM drive) to 
higher available letters. (You must do this or C: will be taken once 
it becomes available. After reassigning C:, you should receive a 
message requiring you to reboot for the new assignment to take 
effect.
2. Reboot the server.
On system restart you may receive virtual memory errors; this is normal.
3. Rename all drives to their original letters.
4. Reboot and make an ERD of the new configuration.
Installing Multipath 
and Failover 
Software
Multipath and failover software on the host can transfer control of 
storage system LUNs on a hardware failure in a LUN path.
Important:
 If the Navisphere Host Agent is installed, you must 
remove it before installing multipath and failover software. (Refer to 
the documentation that came with your failover software.) Reinstall 
the host agent after installing the multipath and failover software.
Follow these steps to set up the multipath and failover software:
1. Install the software as described in the your EMC ControlCenter 
Navisphere Management software, ATF, or PowerPath 
documentation.
2. Create and enable a zone for each additional HBA and SP port 
that will be supported by the multipath and failover software.
Refer to Known Issues on page 3-35 for any additional information.