Emerson CC1000DM User Manual

Page of 64
S E T U P
Operational Checks
2-10
2
Po w e r  R e q ui re m en t s    
Be sure your power supply is sufficient for the board. The combined power (3.3 volts 
and 5 volts) for a CC1000dm is 27 watts. 
E nv i ro n me nt a l  C o ns i d er a t i o ns    
As with any printed circuit board, be sure that air flow to the board is adequate. Chassis 
constraints and other factors greatly affect the air flow rate. The environmental require-
ments are as follows:.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 
O P E R A T I O N A L   C H E C K S
All products are tested before they are shipped from the factory. When you receive your 
CC1000dm, follow these steps to assure yourself that the system is operational:
1
Visually inspect the board for components that could have loosened during shipment.
2
Verify that the front panel is secure.
3
By default, the CC1000dm carrier card is configured to support 3.3 V I/O operation on the 
secondary bus. Please be sure to select the appropriate voltage for your application.
Voltage:
Range:
Typical Current 
(amps):
Usage:
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
+3.3 V
+5/-3%
1.0
Board logic
+5 V
+5/-3%
0.4
Board logic 
+12 V
±5%
0.5 
PMC slot power
–12 V
±5%
0.5 
PMC slot power
VIO
±5%
0.75 
PCI signaling for board logic
Voltage:
Usage:
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 
Operating Temperature
0 to +55
O
 Centigrade, ambient (at board)
Relative Humidity
Not to exceed 95% (non-condensing)
Storage Temperature
-40 to +85
O
 Centigrade, ambient
Shock and Vibration
NEBS Level 3 compliant
Table 2-5:                                                                                    
Power Requirements
Table 2-6:                                                                                    
Environmental Requirements