Eicon Networks 800-241 User Manual

Page of 52
34
DIVA Mobile User’s Guide
AT Commands and Result Codes
Note: The AT commands for the V.34 modem are standard modem 
commands which are realised via the hardware of DIVA Mobile.
Factory default settings are stored in permanent memory. Italicized n or x 
denotes options to be supplied by user or software. 
Command
Function
Default
A
Go off-hook and attempt to answer a call.
Bn
Modulation Standard for 0 - 1200 bps
B1
Dn
Dial telephone number
En
Turn off command echo
E1
Hn
On/off-hook
In
Identification commands
Mn
Speaker control
M1
Nn
Automode detection off/on
N1
On
On-line and retrain control
P
Pulse dial
Qn
Result codes enable/disable
Q0
Sn=x
Set register n to decimal value x
Sn?
Get decimal value in register n
T
Tone (DTMF) dial
Vn
Result codes format: verbose/terse
V1
Wn
Extended result code format n
W0
Xn
Result code reporting options
X4
Yn
Long space disconnect
Y0
Zn
Recall stored profile n
&Cn
Carrier detect control
&C1
&Dn
DTR options
&D2
&Fn
Return all settings to factory default n
&Gn
Guard tone disable/enable
&G0
&Kn
Flow control settings
&K3
&P0
Set pps pulse dial with 39%/61% make/break
&P0
&Qn
Connection mode
&Q5
&Rn
CTS control options
&R1