RAD Data comm RIC-155 User Manual

Page of 90
Quick Start Guide 
RIC-155 Installation and Operation Manual 
2 Configuring 
RIC-155 
 
4.  When the ALM LED (red) starts blinking, press <Enter> several times. 
RIC-155 automatically adjusts itself to the current terminal baud rate and 
responds with a string of dots. 
5. Type several dots. 
When the hardware initialization is completed, the SIG and ALM LEDs 
flash rapidly six times. 
6.  Press <Enter> to display the user name and password entry form. 
7.  Enter your user name and password and proceed with the management 
session. 
 
The RIC-155 default user names are SU and USER, default password is 1234
 
Configuring RIC-155 
The management software provides a Quick Setup menu, which includes the most 
basic parameters necessary for configuration. 
 
To configure RIC-155: 
•  From the Quick Setup menu (Main > Configuration > Quick Setup), 
configure the following parameters:  
 
Master Clock 
 
Host IP address 
 
Host IP mask 
 
Default Gateway 
 
Host Tagging 
 
Host VLAN ID 
 
Host VLAN Priority 
 
Forwarding Mode 
 
Physical Port Management Access 
 
SDH/SONET frame type. 
 
Note