Promise Technology TX2200 User Manual

Page of 128
FastTrak TX2200, TX2300 User Manual
86
2.
Replace the failed physical drive.
3.
Rebuild your logical drive.
Identify the Failed Physical Drive
Click on the Physical Drive View 
 icon in the WebPAM user interface. Look for 
a missing physical drive. A drive that used to be present but is suddenly absent is 
the failed disk drive. 
In this example, there were four disk drives connected to the FastTrak Controller. 
Notice that there is no drive on Port 2. This is the failed drive.
Replace the Failed Physical Drive
Replace the failed physical drive with a new one of equal or greater capacity. 
Then rebuild the logical drive. See “Install the Disk Drives” on page 9 and the 
SuperSwap User Manual for more information about replacing a physical drive.
Rebuild Your Logical Drive
1.
Click on the Logical Drive View 
 icon in Tree View.
2.
Click on the Logical Drive 
 icon of the logical drive you want to rebuild.
3.
Click on the Rebuild tab in Management View.
Port 1
No drive 