Promise Technology M300p User Manual

Page of 322
Chapter 5: Management with the CLU
195
iSCSI Management
iSCSI Management deals with all iSCSI settings and functions with the exception 
of network connections and settings. This feature appears only with VTrak iSCSI 
models. Network connections and settings are discussed under “Network 
Management” on page 191.
Node
These functions affect both VTrak iSCSI ports. There are more iSCSI settings 
under iSNS Ports, SLP Ports and CHAP.
Note that Header and Data Digest work best with initiators that have a TCP 
Offload Engine (TOE).
1.
From the Main Menu, highlight iSCSI Management and press Enter.
2.
Highlight iSCSI Node and press Enter.
Node information appears.
3.
Highlight iSCSI Node Settings and press Enter.
This screen enables you to make iSCSI Node Settings.
4.
Highlight the items you want and press the backspace key to erase the 
current value, then type the new value:
Node Name
Node Alias – Maximum of 32 characters. Use letters, numbers, space 
between words and underscore. An alias is optional.
Outstanding R2T
Maximum Burst Length
Default Time to Wait
Default Time to Retain
5.
Highlight the items you want to set and press the spacebar to toggle 
between Enabled and Disabled:
Header Digest
Data Digest
Unidirectional CHAP Authorization
Bidirectional CHAP Authorization
6.
Press Ctrl-A to save your settings.
Ports
1.
From the Main Menu, highlight iSCSI Management and press Enter.
2.
Highlight iSCSI Ports and press Enter.
3.
Highlight iSCSI Port 1 or Port 2 and press Enter.