Promise Technology M300p User Manual

Page of 322
Chapter 8: Troubleshooting
287
Without a Hot Spare Drive
If there is no hot spare drive of adequate capacity, you must remove the failed 
drive and install an unconfigured replacement drive of the same or greater 
capacity in the same slot as the failed drive. Until you install the replacement 
drive, the logical drive will remain Degraded.
If the Auto Rebuild function is ENABLED, the disk array will begin to rebuild 
automatically as soon as you replace the failed drive. 
If the Auto Rebuild function is DISABLED, you must manually rebuild the 
disk array after you replace the failed drive. 
To enable Automatic Rebuild, see page 71 (WebPAM PROe) or page 200 (CLU).
To set Hot Spare Policy, see page 150 (WebPAM PROe) or page 202 (CLU)
Rebuild Operation
 
During rebuild: 
The alarm sounds a single short beep, repeated 
No warning icon displays over the Disk Array or Logical Drive 
The Management Window reports the Disk Array’s Operational Status as 
OK, Rebuilding.
Important
If your replacement disk drive was formerly part of a different disk 
array or logical drive, you must clear the configuration data on the 
replacement drive before you use it. 
See “Clear Physical Drive Conditions” on page 126 (WebPAM 
PROe) or “Clear Stale and PFA Conditions” on page 180 (CLU).