Promise Technology M200f User Manual

Page of 322
Chapter 4: Management with WebPAM PROe
117
6.
Check the SMART Log box to enable the Self-Monitoring, Analysis, and 
Reporting System (SMART). 
7.
Enter a polling interval (1 to 1440 minutes) in SMART Polling Interval field. 
8.
Check the Coercion Enabled box to enable disk drive capacity coercion.
When disk drives of different capacities are used in the same array, coercion 
reduces the usable capacity of the larger disk drive(s) in order to match the 
smallest capacity drive.
For more information, see “Capacity Coercion” on page 252.
9.
Select a coercion method from the Coercion Method dropdown menu. The 
choices are: 
GB Truncate – (Default) Reduces the useful capacity to the nearest 
1,000,000,000 byte boundary. 
10GB Truncate – Reduces the useful capacity to the nearest 
10,000,000,000 byte boundary. 
Group Rounding – Uses an algorithm to determine how much to 
truncate. Results in the maximum amount of usable drive capacity. 
Table Rounding – Applies a predefined table to determine how much to 
truncate. 
10. Enter a time interval (1 to 12 seconds) in the Write Back Cache Flush 
Interval field. 
For more information, see “Cache Policy” on page 251.
11. Select a Cache Line Size (8KB or 64KB) from the Preferred Cache Line Size 
dropdown menu.
For more information, see “Cache Line Size” on page 252. 
12. Click the Submit button.
The changes take effect immediately.
Enclosures
The Enclosures–Information tab provides component information about the 
VTrak subsystem enclosure, including:
Enclosure ID number 
Number of power supply units 
Number of fans 
Number of blowers – Blowers are scroll fans, 2 in each cooling unit 
Number of physical drive slots – 15, 12 or 8 depending on the VTrak model 
Number of temperature sensors – The number of sensors varies among 
VTrak models 
Number of voltage sensors – 3.3V, 5.0V, and 12.0V