To create a new disk array:
1.
Click the Subsystem 
 icon in Tree View. 
2.
Click on the Disk Arrays 
 icon. 
3.
Click on the Create tab in Management View. 
4.
From the Create tab dropdown menu, select Express
5.
Check the boxes to select any one or combination of the following: 
Redundancy – The array will remain available if a physical drive fails 
Capacity – The greatest possible amount of data capacity 
Performance – The highest possible read/write speed 
Spare Drive – A hot spare drive is created when you select Redundancy, 
Spare Drive, and five or more unconfigured physical drives are available 
6.
In the Number of Logical Drives field, enter the number of logical drives you 
want to make from this disk array. 
7.
From the Application Type menu, select an application that best describes 
your intended use for this disk array: 
File  Server 
Video Stream 
Transaction Data 
Transaction Log 
Other 
8.
Click the Update button.
Or check the Automatic Update box and updates will occur automatically.
The following parameters display: 
Disk Arrays – The number of physical drives in the disk array, their slot 
numbers, configurable capacity, and the number of logical drives to be 
created 
Logical Drives – The slot number of the logical drive(s), their RAID level, 
capacity, and stripe size 
Spare Drives – The physical drive slot number of the dedicated hot 
spare assigned to this disk array (all RAID levels except RAID 0) 
If you accept these parameters, proceed to the next step.
If you do NOT accept these parameters, review and modify your selections 
in the previous steps. 
9.
When you are done, click the Submit button. 