3.5 Request data from R2600/01
This communication makes it possible to request all values, parameters, configurations, states and equipment markings. 
Thereby, the data is individually addressed per parameter index. See section 4 for the complete list of all parameter indices.
3.5.1
Request an equipment specification
The parameter index lies between 30h and 3Fh. Thus the characters "from/to channel" and "receipt No." in the control and long set are omitted.
Example: Request for equipment marking having the address = 33 = 21h (see 4.4)
Request from master (control set, see 2.2):
Equipment response (long set, see 2.3):
See 2.4.2.2 for the contents of the function field (FF).
The "data block" consists of a character 26h as marking for the R2600/01 (see 4.4).
68h
03h
03h
68h
21h
89
30h
DAh
16h
FF
PI
PS
68h
04h
04h
68h
21h
„FF“
30h
26h
„PS“
16h
PI
Data block