Zhone Technologies 600 User Manual

Page of 240
Server Cards
5-17
ISDN-PRI Card
ISDN-PRI Card User Screens and Settings
TS
The TS (timeslot) setting identifies the timeslot on the WAN link that carries this D channel. 
Even though the system allows values that range from 1-24 for T1 links and 1-31 for E1 links, 
in almost all cases, TS 24 will be used for T1 applications and TS 16 will be used for E1 
applications (when available).
RATE
The Rate parameter allows users to choose the rate of the D channel. Even though the 
equipment allows values of 56k and 64k, in almost all cases, the rate of 64k will be used.
SIDE
The options for this parameter are user (user side) and net (network side). See discussion 
earlier in this chapter that describes which side to choose.
SW. TYPE
The Switch Type is selected from the possible central office equipment types to which the 
system is connected. The choices are fjtsu (Fujitsu), att_4 (AT&T #4ESS), att_5 (AT&T 
#5ESS
®
), dms_1 (DMS-100
®
), dms_2 (DMS-200
®
ni_2 (National ISDN II), dpnss (Digital 
Private Network Signaling System), dass2 (Digital Access Signaling System #2), net_5 
(European ISDN), and mcl.
DATA INV
The Data Inversion option allows users to select whether or not the HDLC (High level Data 
Link Control) will invert the data bits when B8ZS format is not available. In almost all cases, 
DATA INV should be set to no.