Zhone Technologies 600 User Manual

Page of 240
Server Cards
2-7
FRS Card
ACS-FRS Card User Screens and Settings
DCE PARAM
The DCE Parameters setting will show n/a unless a Port Type of u-dce or nni is selected. Once 
set to enable, the user may choose from the following options:
Error Threshold (N392)
Poll Verify Timer (T391)
Events Counter (N393) 
The Error Threshold (N392) counts the errors that will be tolerated during the cast number of 
events as set by the Events Counter before declaring the LMI link down. The number of errors 
options are to 10. The value is input using the keyboard of the control terminal. The default 
is 3.
The Poll Verify Timer (T391) allows you to select the time interval (in seconds) that should 
elapse between “keep alive” messages sent from the corresponding DTE. The number of 
seconds options are to 30. The default is 15 seconds.
The Events Counter (N393) allows you to select the window size for the number of events 
(frames) in which errors will be counted. If error threshold (N392) is exceeded within cast 
N393 frames, the link is declared down. The number of events counted are to 10. The default 
is 4.
DTE PARAM
The DTE Parameters setting will show n/a unless a Port Type of u-dte or nni is selected. Once 
set to enable, the user may choose from the following options:
Error Threshold (N392)
Poll Interval Timer (T391)
Events Counter (N393)
Full Status Frequency (N391)
The Error Threshold (N392) counts the errors that will be tolerated during the cast number of 
events as set by the Events Counter before declaring the LMI link down. The number of errors 
options are to 10. The value is input using the keyboard of the control terminal. The default 
is 3.
The Poll Verify Timer (T391) allows you to select the time interval (in seconds) that should 
elapse between “keep alive” messages sent from the corresponding DCE. The number of 
seconds options are to 30. The default is 15 seconds.