Server Cards
2-25
FRS Card
ACS-FRS Card User Screens and Settings
Table 2-8. LMI Data Screen Actions
STATUS INQ. RX
The Status Inquiry Received figure shows the total number of status inquiry requests received 
by the DCE.
STATUS TX
The Status Transmitted figure shows the total number of “keep alive” and full status inquiries 
sent by the DCE.
ASYNC STATUS TX
If the ASYNC parameter in the ACS-FRS card Main Screen is set to yes for the port, 
asynchronous status packets transmitted by the DCE are tabulated in this figure.
SEQ # MISMATCH
The Sequence Number Mismatch figure shows the total number of sequence number errors 
have been received by the DCE.
TIMEOUTS
The Timeouts figure shows the total number of times that expected requests from the DTE are 
missed.
BAD HDLC FRAMES
The Bad HDLC Frames figure shows the total number of HDLC errors received on this port.
INVALID FRAMES
The Invalid Frames figure shows the total number of short frames or frames with invalid FR 
headers received on this port.