Renesas M306V8T-EPB User Manual

Page of 90
M306V8T-EPB User’s Manual 
2. Setup 
REJ10J0777-0100  Rev.1.00  2005.08.01 
 
Page 25 of 90 
 
2.6 Turning ON the Power 
 
2.6.1 Checking the Connections of the Emulator System 
Before turning the power ON, check the connection of the interface cable with host machine, PC7501, emulation probe, and 
user system. 
 
2.6.2 Turning ON/OFF the Power 
 
Turn ON the power of the emulator and user system as simultaneously as possible. 
 
Turn OFF the power of the emulator and user system as simultaneously as possible. 
 
Do not leave either the emulator or user system powered on, because of leakage current the internal circuits may be 
damaged. 
 
When turning ON the power again after shutting OFF the power, wait for about 10 seconds. 
 
IMPORTANT 
Notes on Power Supply: 
 
 
The emulator's pin Vcc is connected to the user system in order to monitor user system voltage. For this reason, 
the emulator cannot supply power to the user system. Therefore, provide the user system with a separate power 
supply from that of the emulator. 
 
The voltage of the user system should be as follows. 
 3.15 
≤ Vcc1 = Vcc2 = Vcc3 ≤ 3.45 V 
 
Do not change user system power supply voltage after power has been activated.