Pseudorandom Bit Sequence (PRBS) Testing 
To test using PRBS, configure the IE-iMcV-T1/E1/J1-LineTerm, TP/SFP modules for No 
Loopback, and then configure the Transmit Copper Data Source to PRBS.  Configure 
the local device for Loopback and start the test.  Verify the PRBS LED is ON 
indicating no errors are being received. 
 
Installation Troubleshooting 
General Troubleshooting 
•  The copper port can easily be tested using the internal PRBS signal generator and 
detector and a physical wire loop on the copper interface.   
•  The fiber port is internally tested at all times by a working pair of units.  With one 
unit configured for Local Management (S3-2 set OFF) and the other for Remote 
Management (S3-2 set ON), the fiber line is verified if the RM LED is ON at both 
ends of the fiber line.  Under normal operation only the RM LED is ON at both 
HOST and REMOTE. 
•  To test a media converter by itself, first verify that the fiber patch cable is 
appropriate, then follow these steps to test: 
1.  Connect the media converter to the RJ-48 device with a copper cable. 
2.  Loop a single strand of fiber from the transmit port to the receive port of the 
media converter. 
3.  Verify that there is a valid connection for both the RJ-48 and fiber ports on the 
media converter. (No ER or LOS LED ON) 
•  If there is trouble with link connectivity, verify that the cable connection and DIP 
Switch settings are correct.