IMC Networks E1 User Manual

Page of 24
 
•  Required CSU line Buildout  (0db to -22db) 
•  Receiver BOOST for T1 and E1 applications 
•  Fiber transceivers must be for appropriate fiber run, i.e. (SM or MM) 
•  Management location must be at HOST unit 
Managed Modules 
The IE-iMcV-T1/E1/J1-LineTerm, TP/SFP modules are installed as a HOST-REMOTE 
pair and can be remotely managed when the HOST is installed in an iMediaChassis 
with an SNMP Management module.   
For a managed environment, first manually configure the desired features through 
DIP Switch settings to ensure this configuration is maintained if management is ever 
lost.  After the module is installed, the SNMP enabled features for troubleshooting 
can be modified by using the included iView
2
 SNMP management software.  Ensure 
the software settings match the desired configuration requirements for the installation 
as the chassis may maintain an old setting from a previous installation for that slot 
location.  Module Details will provide information such as serial number, date code 
and part number.  Please download the current SNMP firmware and iView
2
 software 
to ensure all functionality of the modules. 
NOTE 
If installing an IE-iMcV-T1/E1/J1-LineTerm, available in a fixed fiber transceiver model (series 
850-141XX), as a Host and an IE-iMcV-T1/E1/J1-LineTerm with SFP and Configuration Control 
(850-18100) as a Remote, connectivity will be established and data will pass. However, there 
is no possibility of obtaining DDMI information of the SFP from the Remote end, since the 
Host is not capable of it. If the Host and the Remote units are both IE-iMcV-T1/E1/J1-
LineTerm with SFP and Configuration Control, then the Host can extract DDMI information 
from the SFP at the Remote end.