RATOC Systems CB31U User Manual

Page of 104
69
7. Linux
      Linux
    --disc5=off   : disable Disconnect only with SCSI-ID 5
    --sync_all=<20 | 10 | 5 | async>
         To set Transfer rate for all SCSI ID
         (for example)
           --sync_all=10    : 10MB/sec for all SCSI-ID
           --sync_all=async : Async. transfer for all SCSI-ID
    --sync<n>=<20 | 10 | 5 | async>
         To set Transfer rate for spesific SCSI ID
         (for example)
           --sync3=10    : 10MB/sec only for SCSI-ID 3
           --sync5=async : Async.transfer only for SCSI-ID 5
[format]
  # ascconf -v
  PCI30HX, CB31 scsi configuration utility ....
  AdvanSys ASC3050/ASC3350 found. I/O Base = 0800
  View EEPROM Setting : ID-0  ID-1  ID-2  ID-3  ID-4  ID-5  ID-6  ID-7
  Enable Disconnect   :   on   off   off    on    on    on    on    on
  Synchronous transfer: 10MB   5MB  20MB  20MB  20MB  Async 20MB  20MB
  # ascconf --disc_all=on --sync3=10
  PCI30HX, CB31 scsi configuration utility ....
  AdvanSys ASC3050/ASC3350 found. I/O Base = 0800
  View EEPROM Setting : ID-0  ID-1  ID-2  ID-3  ID-4  ID-5  ID-6  ID-7
  Enable Disconnect   :   on    on    on    on    on    on    on    on
  Synchronous transfer: 10MB   5MB  20MB  10MB  20MB  Async 20MB  20MB