Moxa Technologies IA5150 User Manual

Page of 108
NPort IA5150/5250 Series User’s Manual 
Web Console Configuration 
 
5-25
Destination IP address 2/3/4 
Setting 
Factory Default 
Necessity 
Begin:
Empty 
End: Empty 
IP address range 
E.g., Begin: 
192.168.1.11 
   End: 
 
192.168.1.20 
Port: 4001 
Optional 
Local listen port 
Setting 
Factory Default 
Necessity 
1 to 65535 
4001 
Required 
The UDP port that NPort IA5150/5250 listens to, and that other devices must use to contact NPort 
IA5150/5250. To avoid conflicts with well known UDP ports, the default is set to 4001. 
Pair Connection Mode 
Pair Connection Mode employs two NPort IA5150/5250 device servers in tandem, and can be 
used to remove the 15-meter distance limitation imposed by the RS-232 interface. One NPort 
IA5150/5250 is connected from its RS-232 port to the COM port of a PC or other type of 
computer, such as hand-held PDAs that have a serial port, and the serial device is connected to the 
RS-232 port of the other NPort IA5150/5250. The two NPort IA5150/5250 device servers are then 
connected to each other with a cross-over Ethernet cable, both are connected to the same LAN, or 
in a more advanced setup, they communicate with each other over a WAN (i.e., through one or 
more routers). Pair Connection Mode transparently transfers both data and modem control signals 
(although it cannot transmit the DCD signal) between the two NPorts.   
Pair Connection Master Mode 
When using Pair Connection Mode, you must select Pair Connection Master Mode for the 
Operation mode of one of the NPort IA5150/5250 device servers. In effect, this NPort 
IA5150/5250 will be acting as a TCP client. 
 
TCP alive check time 
Setting 
Factory Default 
Necessity 
0 to 99 min 
7 min 
Required 
0 min: TCP connection is not closed due to an idle TCP connection. 
1 to 99 min: NPort IA5150/5250 closes the TCP connection automatically if there is no TCP 
activity for the given time.