Moxa Technologies IA5150 User Manual

Page of 108
NPort IA5150/5250 Series User’s Manual 
Web Console Configuration 
 
5-33
 
ATTENTION 
Consult your Network Administrator or ISP for the proper mail server settings. The Auto 
warning function may not work properly if it is not configured correctly. NPort IA5150/5250 
SMTP AUTH supports LOGIN, PLAIN, CRAM-MD5 (RFC 2554).
 
SNMP Trap Server 
SNMP trap server IP or domain name 
Setting 
Factory Default 
Necessity 
IP address or Domain Name 
None 
Optional 
Event Type 
 
Cold start 
This refers to starting the system from power off (contrast this with warm start). When performing 
a cold start, NPort IA5150/5250 will automatically issue an Auto warning message by e-mail, or 
send an SNMP trap after booting up. 
Warm start 
This refers to restarting the computer without turning the power off. When performing a warm 
start, NPort IA5150/5250 will automatically send an e-mail, or send an SNMP trap after rebooting. 
Authentication failure 
The user inputs a wrong password from the Console or Administrator. When authentication failure 
occurs, NPort IA5150/5250 will immediately send an e-mail or send an SNMP trap. 
IP address changed 
The user has changed NPort IA5150/5250’s IP address. When the IP address changes, NPort 
IA5150/5250 will send an e-mail with the new IP address before NPort IA5150/5250 reboots. If 
the NPort IA5150/5250 is unable to send an e-mail message to the mail server within 15 seconds, 
NPort IA5150/5250 will reboot anyway, and abort the e-mail auto warning.