ZyXEL Communications ZyAIR 100 User Manual

Page of 59
ZyAir 100 Wireless PC Card 
Problems Communicating With the Computer 
 
Table 5-4 Troubleshooting Communication Problems 
PROBLEM 
CORRECTIVE ACTION 
The ZyAIR 100 client cannot 
communicate with the other 
computer in the Ethernet 
when the Infrastructure 
mode is configured. 
Make sure that the Access Point and associated computer are on. 
Use the Site Survey utility to verify operating radio channel has low 
interference. Change the Access Point and all the stations within the BSS 
to another radio channel if interference is high. 
Make sure that the computer and Access Point share the same security 
option. 
Make sure that the BSS ID is the same as the Access Point for a roaming-
disabled station. Make sure the SS ID is the same as the Access Point for 
a roaming-enabled station. 
Site Survey utility shows all 
channels at high 
interference (red bars) 
Move your computer closer to the Access Point within the transmission 
range. 
There are too many wireless clients.  Stop or turn off any unnecessary 
wireless clients.  
 
 
 
 
5-3  