P-971M User’s Guide
Chapter 5 Introduction to CLI
50
5.6.2  CM Commands
The following table describes the 
CM
 commands. By default, you access the 
CM
 group of 
commands when you log into the CLI every time. Use the 
CM
 commands to perform basic 
system settings, diagnostics or configuration file maintenance.  
Table 5   CM Command Summary  
COMMAND
DESCRIPTION
load_config  
<IpAddress> 
<Filename{127}>
Uploads a text based configuration from a TFTP server. 
After the upload process is complete, the device executes 
the commands line by line.
logout
Exits from the CLI session. 
ping  
<IpAddress>
Tests the connection to a device. Specify the IP address 
of the device in dotted decimal notation (for example, 
192.168.1.1). 
reset
Restarts the device. 
Note: All unsaved configuration changes are 
lost once you restart the device. 
restoreDefaults
Resets the device back to the factory defaults. 
Note: All your settings will be erased. 
run_app
Executes channel band  scanning.
save
Saves configuration changes to memory. 
scan_band  
<Band{0..31}>
Sets the predefined scan band (Bitmap).
scan_set  
<index{0..4}> 
<Band{1..5}> <start> 
<end> [freq_offset]
Sets the scan profile set. You can configure up to five 
scan profiles in the set. The Prestige scans all profiles 
when you activate band scanning.
The frequency offset (
freq_offset
) is only applicable 
for European scan plan. 
scan_set_clear
Clears the scan profile. 
scan_show
Displays scan profile setting. 
telnet_pass
<Password{15}>
Sets the Telnet administrator login password. 
telnet_user
<Name{15}>
Sets the Telnet administrator login username. 
version
Displays the firmware version. 
web_admin_id
<WebAdminId{15}>
Sets the web configurator administrator login username. 
Note: You must save the changes and restart 
the device to make the changes take 
effect.