Multi-Tech Systems 7600 User Manual

Page of 372
Network Setup
 ION 7500 / ION 7600 User’s Guide
Page 36
Chapter 2 - Using The Front Panel 
Network Setup
This menu item allows you to configure the Ethernet communications channel. 
The following settings can be configured in this option:
Network settings can be configured automatically with BootP or manually 
through the front panel. (You can also configure network settings via Designer or 
ION Setup software — see “Using ION Software” on page 87 of this manual for 
more information.)
Configuring Network Settings with BootP
The BootP network setting is enabled by default. When a BootP server is set up 
with the correct information, the network settings (IP Address, Subnet Mask, 
Gateway, and SMTP Mail Server IP Address) automatically configure. 
Ask your Network Administrator whether a BootP server has been set up on your 
network. If it has, and your Network Administrator has allocated the required 
network settings on the BootP server, then all of the network settings (that your 
facility requires) automatically appear on the Network Setup screen. 
Setting
Description
Default
IP BootP 
Option
A BootP server automatically sets the IP Address, 
Subnet Mask, Gateway, and SMTP Mail Server IP 
Address
– see your Network Administrator to determine if BootP 
is used
If the IP BootP Option is set to BootP mode, then no 
network settings can be changed
BootP
(Only meter’s ordered with the Ethernet option are set to BootP by 
default; the default is otherwise set to Manual.)
IP Address
Sets the IP Address for the meter
If a BootP server has been correctly set up, the IP Address number 
appears.
If no BootP server has been set up (e.g. you wish to configure 
settings through the front panel) then the default is None.
Subnet Mask
Used if subnetting applies to your network
– see your Network Administrator to determine if 
Subnet Mask is used
If a BootP server has been correctly set up, and Subnet Mask is 
used, then the Subnet Mask address number appears. If Subnet 
Mask is not used, then the default is None.
If no BootP server has been set up (e.g. you wish to configure 
through the front panel) then the default is None.
Gateway 
Used in multiple network configurations
– see your Network Administrator to determine if 
Gateway is used
If a BootP server has been correctly set up, and Gateway is used, 
then the Gateway address number appears. If Gateway is not 
used, then the default is None.
If no BootP server has been set up (e.g. you wish to configure 
through the front panel) then the default is None.
SMTP 
Address
Sets the IP Address for the SMTP Mail Server that is 
configured to forward mail from the meter to the final 
destination 
– see your Network Administrator to determine if the 
SMTP Mail Server is used
If a BootP server has been correctly set up, and an SMTP Address is 
used, then the SMTP Address address number appears. If an SMTP 
Address is not used, then the default is None.
If no BootP server has been set up (e.g. you wish to configure 
through the front panel) then the default is None.