LP225 RS-232 Command Values 
Communication Configuration
 
To control one of the above noted projectors from an RS-232 control system, connect the serial cable or a null modem cable and 
the InFocus RS-232 Adapter (SP-CWRS232) and set the control system serial port settings to match the following communication 
configuration*:
 
RS-232 Port Settings
 
Setting
 
Value
 
Bits per second
 
19,200
 
Data bits
 
8
 
Parity
 
None
 
Stop bits
 
1
 
Flow control
 
None
 
Emulation
 
VT100
 
RS-232 Connection for LP225
 
The RS-232/serial connection for these projectors is located on the PC side of the CableWizard II connection hub. Use the serial 
cable (IFS part # 210-0107-xx) to connect the CableWizard II to the serial port of the computer source.
 
Note: CableWizard
3
 (p/n SP-CW3) does not support RS-232. You must Use CableWizard II (p/n SP-CW2) and the InFocus 
serial cable.
 
Command Format
 
All commands consist of 3 alpha characters followed by a request, all enclosed in parentheses. The request can be a read request 
(indicated by a "?") or a write request (indicated by 1 to 4 ASCII digits).
 
A read request example: 
 
(AAA?) where
 
( starts the command
 
AAA denotes the command
 
? denotes the read request
 
) ends the command 
A read command returns the range and the current setting, for example:
 
Read Command Examples
 
Function
 
Command
 
Response
 
Brightness
 
(BRT?)
 
(0-22, 10)
 
Volume
 
(VOL?)
 
(0-80, 0)
 
Lamp Hours
 
(LMP?)
 
(0-9999, 421)