Adtran OPTI-3 CPE Leaflet

Page of 2
JOB
A
ID
61184002L4-22B
0401
OPTI-3 
CONTROLLER 
CLEI: SOI4JN4D_ _
OPTI-3
ENABLE
TEST
APS
ACO
1184002L4
CRAFT
1550nm
STATUS OPTICS DS3-1
ACO
DS3-2 DS3-3
DESCRIPTION
The Total Access
®
OPTI-3 Controller Module (OCM) provides an OC-3 interface to the network and three ADD/DROP DS3
interfaces to the Loop.  The OCM can be configured for a point-to-point configuration or subtended from 3rd party SONET
equipment.  The OCM operates in terminal mode only.  The compact design mounts in either a rackmount or wallmount
chassis, requiring less space and provides optional redundancy.  It can automatically switch to the offline unit in the event of
optical signal failure or degradation.  The modules are fully hot-swappable. 
Compliant with SONET standards, the OCM functions as a terminal multiplexer.  It supports 1+1 OC-3 equipment and facility
protection, 1:1 OC-3 equipment protection (system provisioned for optical Ycable), 1:1 DS3 facility protection, and detects
standard optical related alarm conditions.  The OCM can be configured to operate redundantly with optional protection of
the optics components.  It can be upgraded online from un-protected to protected and operating software can be upgraded
remotely in Back-to-Back configurations.
The OCM is easily managed with TL1 commands over the Data Communications Channel (DCC) or via Command Line
Interface (CLI) through the local craft interface.  Additional features include remote alarm transport via DCC and alarm
reporting to legacy alarm systems.
FIRMWARE RELEASE
This job aid relates to OPTI-3 System Release 1.3 (Dseries).  The menus and functionality are an extension of the prior system
release (OPTI-3 System Release 1.2 - Cseries).  The latest software is not compatible with System Release 1.1 (Bseries).
INSTALLATION
The Total Access OPTI-3 can be installed in either a Rackmount Chassis (RMC), P/N 1184003L1, or a Wallmount Chassis
(WMC), P/N 1184001L1.  The RMC provides two OCM slots, side by side, with slot A on the left and slot B on the right.  (See
Figure below.)  The WMC provides two OCM slots, positioned vertically with slot A below slot B.  Ensure the appropriate 
chassis is installed before proceeding with the OCM installation. 
Carefully insert the OCM halfway into the selected slot.  Route the fiber cables through the notch on the OCM front panel and
approximately 4 inches past the SC receptacles (to create slack).  Gently but firmly push the OCM all the way into the slot,
being careful not to pinch the fibers between the front panel and the shelf.  Push the latch/ejector tab toward the front panel
to lock it into place.
WARNING: Once fully inserted into the chassis, the module will be powered (provided power is connected to the chassis).
When the OCM powers up, it performs a self-test.  The front panel LEDs illuminate for approximately 8 seconds.  The self-test
is complete once the STATUS LED illuminates green. 
If installing a redundant system, repeat the preceding procedure for slot B.  If not installing a second OCM, a blank faceplate
(P/N 1184005L1) must cover the empty slot.
C A U T I O N 
C A U T I O N ! 
SUBJECT TO ELECTROSTATIC DAMAGE
OR DECREASE IN RELIABILITY.
HANDLING PRECAUTIONS REQUIRED.
■ 
For a complete Installation and Maintenance Practice (P/N 61184002L4-5): 877-457-5007, Faxback Document 964.  Please have your fax number ready.  
LED STATUS
STATUS
Green
In-Service
Yellow
Unit is Out-of-Service – Unassigned
Flashing Yellow Unit is Out-of-Service – Maintenance or is ONLINE and inhibited
from switching
Red
Unit has an equipment failure
OPTICS
Green
Normal Operation
Yellow
Soft failure (e.g. RDI)
Flashing Yellow Unit in Test (e.g. Loopback)
Red
LOS, LOL, and other hard alarms on optical interface
Flashing Red
Unit in Test (e.g. Loopback) with an alarm present on the Optical
Interface
DS3-1 – DS3-3
Green
Unit is ONLINE (DS3 TX ON)
Yellow
Soft failure (e.g. RDI)
Flashing Yellow Unit in Test (e.g. Loopback)
Red
LOS, LOL, and other hard alarms on DS3 interface
Flashing Red
Unit in Test (e.g. Loopback) with an alarm present on the DS3
Interface
ACO
Yellow
When displayed on the OCM at the CO, indicates acknowledged
active alarms at the RT
Flashing Yellow When displayed on the OCM at the CO, indicates an unacknowl-
edged active alarms at the RT
Red
Acknowledged alarms active on the shelf
Flashing Red
Unacknowledged alarms active on the shelf
APS PUSHBUTTON
When depressed simultaneously with the TEST/ENABLE switch on the Offline unit, a switch is forced
between the two OCMs.
When depressed with the TEST/ENABLE switch on the Online unit, it toggles LOCKOUT status.
TEST/ENABLE BUTTON
When depressed alone, tests all unit LEDs (multicolor LEDs appear YELLOW).
When depressed simultaneously with the APS switch on the Offline unit, a switch is forced between
the two OCMs.
ACO BUTTON
When depressed after an audible alarm is sounded, silences the alarm.
When depressed after any other alarm is triggered, acknowledges alarm.
CRAFT INTERFACE
Provides menu access via RS-232 (Craft) port on the front panel.
Connects to VT100 compatible terminal using a DB-9 serial cable.
Requires setting VT100 terminal emulation (to 9600, 19200, 38400, 57600, or 115200 bps), 8 Data Bits,
No Parity, 1 Stop Bit, and No Flow Control.  (The baud rate default is 9600 bps, which can be 
modified through the VT100 menu system.
Provides access to both OCMs installed in the chassis with connection to either OCM craft port.
NOTE: The OPTI-3 is an LR (long reach) optical product. When interfacing with IR (intermediate
reach) 3rd party equipment, the optical receive signal may need to be padded to avoid 
overloading the optical receive signal. The receive signal level should be within 
8 dbm to 
28 dbm for IR equipment.
WARRANTY
ADTRAN will replace or repair this product within the warranty period if it does not meet its published
specifications or fails while in service.  Warranty information can be found at  www.adtran.com/warranty.
U.S. and Canada customer Faxback: 877-457-5007, Document 414.
1
2
3
#61184002L4-22B#
TOTAL ACCESS OPTI-3 CONTROLLER MODULE
1550 NM