Adtran NetVanta T1/FT1 Leaflet

Page of 2
NetVanta T1/FT1 Network Interface Module (NIM)
P/N 1202862L1
For more detailed documentation, visit us online at 
Quick Start Guide
®
Quick Start Guide, 61202862L1-13D, November 2006
Copyright © 2006 ADTRAN, All Rights Reserved
S
PECIFICATIONS
Operating Modes Frame Relay, Multilink Frame Relay, 
PPP, Multilink PPP, HDLC
T1/FT1 Interface
Supported Standards: AT&T TR 62411, 
AT&T TR 54016, Bellcore TR 194, ANSI T1.403
Line Rate: 1.544 Mbps ±75 bps
Line Code: AMI or B8ZS
Framing: D4 (SF) or ESF
FT1 Line Rate: DS0 channelized (multiples of 
64 kbps)
Input Signal: 0 to -36 dB (DS1)
Line Build-Out: 0, -7.5, -15, -22.5 dB (long), 
0 to 655 ft (short)
DS0 Assignment: Programmable
Connector: RJ-48C
Clock Source
Network, Internal
Diagnostics
Test Pattern Generation and Detection: QRSS, 511, 
2
15
 - 1, 2
20
 - 1, all ones, all zeros
Network loopbacks (local and remote); responds to 
both inband and FDL loop codes
Alarm generation and detection
Network and user sets of performance data 
(15 minutes and 24 hours)
Compliance
FCC Part 15 Class A, EN 55022 Class A
ACTA/FCC Part 68, IC CS-03
UL/CUL 60950
Physical
Dimensions: 2.75-inch W x 4.25-inch D
Operating Temperature: 0°C to 50°C
Storage Temperature: -20°C to 70°C
Relative Humidity: Up to 95 percent, noncondensing
NetVanta modules should be installed only in 
NetVanta Series products.
WAN-T1
DBU
I
NSTALLATION
 I
NSTRUCTIONS
1.
Remove the power from the unit.
2.
Slide the option module into the option slot until the module is 
firmly seated against the chassis.
3.
Secure the pins at both edges of the module.
4.
Connect the cables to the associated device(s).
5.
Complete installation of the base unit.
6.
Restore power to the unit.
For NetVanta modules with outside plant 
connections, ensure that all cables are 
removed from the module before installing or 
removing it from the NetVanta chassis.
WAN-T1 N
ETWORK
 (RJ-48C) C
ONNECTION
 P
INOUTS
Pin
Name
Description
1
R1
Receive data from the network - Ring 1
2
T1
Receive data from the network - Tip 1
3
Unused
4
R
Transmit data toward the network - Ring
5
T
Transmit data toward the network - Tip
6-8
Unused
An optional Dial Backup Interface Module (DIM) is 
required for dial backup applications.
For a description of the DBU pinouts, refer to the 
Quick Start Guide included with your DIM 
shipment.
Important: For additional details on product 
features, specifications, installation, and safety, refer 
to the appropriate Hardware Installation Guide on 
the ADTRAN OS System Documentation CD 
shipped with the base unit and available online at 