Adtran MX2820-48 VDC M13 MUX Leaflet

Page of 2
C A U T I O N ! 
SUBJECT TO ELECTROSTATIC DAMAGE
OR DECREASE IN RELIABILITY.
HANDLING PRECAUTIONS REQUIRED.
MX2820
M13 MUX
P/N 1186002L5
CLEI:  M3C3WG0ATA
MX2820 –48 VDC M13 MUX
1186002
M13 MUX
ALM
ACT
TEST
STAT
TEST
STAT
DS1
DS3
#61186002L5-22A#
DESCRIPTION
The MX2820 M13 MUX is a plug-in unit for the MX2820 chassis that provides an M13 
multiplexer function to the MX2820 system. Two MX2820 M13 MUX cards are used together 
to provide a redundant M13 multiplexer circuit. The MX2820 M13 MUX:
provides 1:1 redundancy
meets the requirements for NEBS Level 3.
INSTALLATION AND TURNUP
After unpacking the unit, inspect it for damage. If damage is found, file a claim with the carrier 
and then contact ADTRAN Customer Service. Refer to the Warranty Statement on this Job Aid.
This module occupies a MUX slot in the MX2820 chassis. To install the M13 MUX in the 
chassis, perform the following steps:
1. Pull the ejector tab into the down position and gently but firmly push the MUX into the 
selected MUX slot. Simultaneous thumb pressure at the top and at the bottom of the unit 
will ensure a good seat of the MUX into the backplane connector. 
2. Push the ejector tab up and closed against the front panel.
Upon installation, the MUX will begin a self-test. This is followed with the LEDs reflecting 
the true state of the hardware.
OPERATIONAL SPECIFICATIONS
Operates from A or B –42 VDC to –56 VDC input voltage power feeds.
Operates over extended temperature range of –40ºC to +50ºC without fans 
 
or –40ºC to +65ºC with fans.
Storage –40ºC to +85ºC. Relative humidity to 95 percent, noncondensing.
COMPLIANCE
The MX2820 M13 MUX complies with UL 60950, NEBS Level 3, and 
 
GR-1089-CORE.
The MX2820 M13 MUX is intended for installation in restricted access areas only.
The MX2820 M13 MUX is intended for installation in a Type “B” or “E” enclosure.
This device complies with Part 15 of the FCC rules. Operation is subject to the following two 
conditions: (1) This device may not cause harmful interference, and (2) this device must accept 
any interference received, including interference that may cause undesired operation.
Changes or modifications not expressly approved by ADTRAN could void the user’s authority 
to operate this equipment.
PROVISIONING
All provisioning of the MX2820 M13 MUX will be handled through the SCU. The menu tree 
on the reverse of this Job Aid provides the options and default settings for the MX2820 M13 
MUX.  NOTE: When provisioning the L5 MUX, use the menu tree on this Job Aid, rather than 
the manual, as there are some code differences in the MX2820 Manual.
Code
Input
Output
Power Code
C
C
Telecommunication Code (TC)
Installation Code (IC)
A
LED STATUS FOR ACTIVE MUX
LED STATUS FOR STANDBY MUX
ACT
!
Green
Normal (All OK)
!
/
!
  Green/Amber (Alternating)
Normal and console open
!
Red
Self-test failed
!
Amber
Software update in progress
!
/
!
Red/Amber (Alternating)
Self-test failed and console open
4
Red (Flashing)
Module has failed
ALM
!
Green 
No critical, major, or minor alarms
!
Red
Major or minor alarm in progress
4
Red (Flashing)
Critical alarm in progress
DS3 STAT
!
Green
Normal (DS3 OK)
!
Red
AIS, OOF, RAI, Idle alarms
4
Red (Flashing)
DS3 LOS or DS3 Failure (critical)
4
Red (Flashing once per event) Single/Burst DS3 code violations
!
/
!
Red/Green (Alternating)
DS3 XCV threshold exceeded
DS3 TEST
"
Off
No DS3 tests in progress
!
Amber
In test (locally originated)
4
Amber (Flashing)
In test (remotely originated)
DS1 STAT
"
Off
All DS1s are disabled
!
Green
Enabled DS1s normal (All OK)
!
Red
Non-critical DS1 alarm (CAIS, LAIS)
4
Red (Flashing)
LOS on an enabled line (critical DS1 
alarm; non-critical system alarm)
4
Red (Flashing once per event) Single/Burst RX DS1 code violation
!
/
!
Red/Green (Alternating)
DS1 XCV threshold exceeded
DS1 TEST
"
Off 
No DS1 tests in progress
!
Amber
In test (locally originated)
4
Amber (Flashing)
In test (remotely originated)
ACT
4
Green (Flashing)
Normal (All OK)
!
Amber
Software update in progress
4
Red
Failure
ALM
"
Off 
Permanent state during standby
DS3 STAT
"
Off
Normal (DS3 OK)
4
Red (Flashing)
In test (remotely originated)
DS3 TEST
"
Off 
Permanent state during standby
DS1 STAT
"
Off Normal 
(DS1s 
OK)
4
Red (Flashing)
DS1 Failure
DS1 TEST
"
Off 
Permanent state during standby
61186002L5-22A
0408