Acer AcceleRAID 170 User Manual

Page of 86
Implementation
C-2
AcceleRAID 170 Installation Guide
• odineb.nlm - This is a module combining the Open Data-link interface 
and the Novell Event Bus (NEB). The NEB controls the device drivers 
through the Open Data-link.
If the NetWare installation process determines that the server supports PCI 
Hot Plug and detects the appropriate driver, the installation process adds the 
following two LOAD commands to the autoexec.ncf file:
• LOAD sys:\system\driver_name 
This command loads the bus driver (for Compaq, this is cpqsbd.nlm). 
After this command is executed, NetWare autoloads ncm.nlm.
• #LOAD sys:\system\ncmcon.nlm
This command loads the Novell Configuration Manager Console, 
which then loads odineb.nlm. These commands can also be executed at 
the server console prompt.
Note
This command is commented out. If you want the 
Configuration Manager Console to be loaded every 
time the system is started, remove the pound sign (#) 
at the beginning of the line.
Perform the following steps:
1. Install NetWare 5 Service Patch 1.
2. Install the Mylex GAM DMI driver.
3. Restart the server. The autoexec.ncf will execute and load the drivers 
and start ncmcon.nlm (the PCI Hot Plug user interface).
Note
If any LOAD line is commented out in autoexec.ncf
the corresponding driver can be loaded manually by 
executing the LOAD command (as listed in 
autoexec.ncf) at the server console prompt.