ADC and 3 Doubler User Manual

Page of 44
LTPH-UM-1234-01
 
Loopback Operation in HiGain Systems
HDU-409 Lists 1, 2, and 3
April 30, 2003
 23
The SPLB generic command set for four-doubler loopbacks is listed in 
. The commands are specific combinations of either 6 or 7 bits that 
continuously repeat. All NDUx loopbacks are towards the network. All 
CDUx loopbacks are towards the customer. 
 is a diagram 
of the various HiGain loopbacks.
Table 7.
SPLB Generic Command Set
Command Set
Loopback
NDU1 
1 1 0 0 0 0 (2-in-6)
NDU2 
1 1 1 0 0 0 (3-in-6)
NDU3 
1 0 1 0 0 0 1
NDU4 
1 0 1 0 0 1 0
CDU1 
1 1 1 1 0 0 (4-in-6)
CDU2 
1 1 1 1 1 0 (5-in-6)
CDU3 
1 0 1 1 0 0 1 
CDU4 
1 0 1 1 0 1 0