ADC DL3XR-FCA100 User Manual

Page of 52
Local Configuration
 
 LTPS-UM-8013-03
32
August 30, 2002
 D3LX CO and RMT Modules
R
EMOVING
 D3LX M
ODULES
Figure 19.
Removing a D3LX Module–D3LX CO Shown
1
For SC-type connectors: pull down on the retaining latch and withdraw the unit halfway out of the chassis 
while preventing the fiber-optic cord from binding. Release the fiber-optic patch cord from the optical 
receptacle by gently pulling back on the locking mechanism and remove the cord as shown in 
2
For FC-type connectors: unscrew the threaded cap counterclockwise and withdraw the unit halfway out of 
the chassis while preventing the fiber-optic cord from binding. 
3
Replace the protective cap on the optical connector located on the circuit board.
Do not look into the ends of any optical fiber or into any plug-in module connector. Exposure to 
invisible laser radiation may cause permanent eye damage. A meter should be used to verify 
active fibers. 
LEC
D3LX CO
STATUS
DS3 STATUS
ENABLE
DS3 ONLINE
FAR END
Optical connector
Fiber patch cord
D3LX module
Optical receptical