ADC DL3XR-FCA100 User Manual

Page of 52
LTPS-UM-8013-03
 Remote 
Configuration
D3LX CO and RMT Modules
August 30, 2002
 35
1
From the Main menu, select 3. Unit Configuration.
2
Within the Unit Configuration screen (see 
), select the Group number that corresponds to 
the D3LX circuit you want to configure, based on the module’s position in the remote unit.
3
Select each field parameter and move from field to field as shown in 
. Assign the selections by 
pressing .
4
Repeat Steps 1 and 2 for each D3LX RMT system installed in the chassis.
Leave Unit Service State field set to OOS (Out of Service) until the Unit Equip State has been set. 
This prevents false alarms. Set the Unit Service State to IS (In Service).
Table 7.
Unit Configuration Fields–D3RCAM Version 1.0 or later
Field Name
Type
Options
Description
Default
Unit Equip State
Toggle
EQUIPPED
Establishes communication with D3RCAM. 
Module must be set to EQUIPPED before 
remaining selections are allowed.
UNEQUIPPED
UNEQUIPPED
No communication with D3RCAM.
Unit Service State
Toggle
IN SERVICE
Places the unit in service and allows equipment 
alarm reporting by the D3RCAM. Must be set to 
IS for reporting of equipment alarms.
OOS
OUT OF SERVICE
Removes unit from service and stops 
equipment alarm reporting by the D3RCAM.
Unit Protect State
Toggle
PROTECTED
Line protection
Unprotected
UNPROTECTED
No protection
DS3 Provisioned
Toggle
YES
Brings up DS3 default settings and allows 
configuration changes.
NO
NO
No configuration changes allowed.
DS3 Service State
Toggle
IN SERVICE
Select IS after completing the remaining con-
figurations.
OOS
OUT OF SERVICE
Leave this field at OUT OF SERVICE (versus IN 
SERVICE) at this time to avoid undesirable 
reporting of alarms. 
Optical Service State
Toggle
IN SERVICE
Places facility in service and enables T3 alarm 
reporting by the D3LX RMT.
OOS
OUT OF SERVICE
Removes facility from service and stops T3 
alarm reporting by the D3LX RMT.
Optical BER Alarm 
Threshold
Toggle
Set to OFF or set 
between 10
-6
 and 10
-10
The average Bit Error Ratios of both the 
incoming optical signals are monitored by the 
D3LX RMT. By monitoring BERs, the D3LX CO 
is capable of triggering a minor alarm when any 
of the monitored signals degrades below the 
BER threshold level.
10
-8
Optical BER Switch 
Threshold
Toggle
Range from 10
-4
 to 
10
-10
 
Sets the threshold at which the APS will be 
executed.
10
-6
DS3 Remote LBO 
Toggle
0–225 ft., 226–450 ft.
The DS3 signal output provides standard DSX 
signal levels which can be compensated for at 
various distances, such as cable length.
0–225 ft.
DS3 Local LBO 
Toggle
0–225 ft., 226–450 ft.
The DS3 signal output provides standard DSX 
signal levels which can be compensated for at 
various distances, such as cable length.
0–225 ft.
ENTER