Lucent Technologies 6000 User Manual

Page of 586
Configuring Individual WAN Connections
The Connection profile
MAX 6000/3000 Network Configuration Guide
 4-21
MRU, LQM and Compression parameters
The following parameters in Ethernet > Connections > Connection profile > Encaps Options 
define the number of bytes the MAX unit can receive in a single frame, Link Quality 
Monitoring (LQM) values and link compression settings for packets and for headers: 
Base Ch Count
Number of channels to use to set up a session initially. If the session 
uses MP, Base Ch Count specifies the total number of channels to be 
used for the call. For an AIM, BONDING, or multichannel PPP call, 
the channel count may be augmented.
Min Ch Count
Minimum number of channels that can be established for a multilink 
call. If this number of channels is not available, the multilink session is 
not established. For optimum performance, both sides of the multilink 
connection should set this parameter to the same value.
Max Ch Count
Maximum number of channels that can be allocated to a multilink 
connection. For optimum performance, both sides of the connection 
should specify the same maximum channel count.
Inc Ch Count
Number of channels the unit adds when bandwidth changes either 
manually or automatically during a call.
Dec Ch Count
Number of channels the unit removes when bandwidth changes either 
manually or automatically during a call. You cannot clear a call by 
decrementing channels.
Parameter
Specifies
Parameter
Specifies
MRU
Maximum number of bytes the unit can receive in a single frame. 
Usually the default is the right setting, unless the far end requires a 
lower number.
LQM
Whether or not the unit requests LQM when answering a PPP call. 
LQM counts the number of packets sent across the link and 
periodically asks the remote end how many packets it has received. 
Discrepancies are evidence of packet loss and indicate link-quality 
problems.
LQM Min
Minimum duration between link-quality reports for PPP connections, 
measured in 10ths of a second.
LQM Max
Maximum duration between link-quality reports for PPP connections, 
measured in 10ths of a second. 
Link Comp
Link-compression method for a PPP, MP, and MP+ calls. Both sides of 
the connection must set the same type of link compression or it is not 
used.
VJ Comp
Whether or not Van Jacobson IP header compression should be 
negotiated on incoming calls using encapsulation protocols that 
support this feature. VJ Comp applies only to packets in TCP 
applications, such as Telnet. Turning on header compression is most 
effective in reducing overhead when the data portion of the packet is 
small.