Lucent Technologies 6000 User Manual

Page of 586
Configuring IP Routing
Configuring WAN interfaces
MAX 6000/3000 Network Configuration Guide
 9-37
configured to acquire its IP address dynamically. For example, the following a sample software 
configuration presumes that the PC has a modem connection to the MAX unit:
Username=victor
Accept Assigned IP=Yes
IP address=Dynamic (or Assigned or N/A)
Netmask=255.255.255.255 (or None or N/A)
Default Gateway=None or N/A
Name Server=10.2.3.55
Domain suffix=abc.com
Baud rate=38400
Hardware handshaking ON
VAN Jacobsen compression ON
Configuring pools using local profiles
To configure the MAX unit to accept dial-in connections from Site B and assign an IP address:
1
Open Ethernet > Mod Config > WAN Options.
2
Set the Pool#1 Start parameter to specify the start address of the pool, and set the Pool#1 
Count parameter to specify the number of contiguous addresses the pool includes. For 
example:
Ethernet
Mod Config
WAN options…
Pool#1 start=10.12.253.1
Pool#1 count=126
Pool#1 name=Engineering Dept.
Pool only=Yes
Pool Summary=Yes
3
Open the Ether Options subprofile, then set the Proxy Mode parameter to Yes.
Ether options…
Proxy Mode=Yes
4
Exit the profile and, at the exit prompt, select the
 
exit and accept
 option.
5
Open the Answer profile and set the Assign Adrs parameter to enable dynamic address 
assignment and set the PPP Options > Route IP parameter to enable IP routing:
Ethernet
Answer
Assign Adrs=Yes
PPP options…
Route IP=Yes
6
Exit the profile and, at the exit prompt, select the
 
exit and accept
 option.
7
Open a Connection profile for the dial-in user.
8
Set the Station parameter to specify the user’s name, set the Active parameter to activate 
the profile, and specify the desired encapsulation options. For example:
Ethernet
Connections
Connection profile 
Station=victor
Active=Yes
Encaps=PPP