Lucent Technologies 6000 User Manual

Page of 586
Configuring IPX Routing
Creating and applying IPX SAP filters
MAX 6000/3000 Network Configuration Guide
 12-23
Ethernet
Mod Config
Ether options...
IPX SAP Filter=1
Ethernet
Answer
Session options...
IPX SAP Filter=2
Ethernet
Connections
Connection profile 1
Session options...
IPX SAP Filter=2
Input SAP filters and output SAP filters
Each filter contains up to eight input filters and output filters, which you define individually 
and apply in order (1–8) to the packet stream. Apply the input filters to all SAP packets the 
MAX unit receives. They screen advertised services and exclude them from or include them in 
the MAX unit’s SAP table as specified by the filter conditions. 
Apply output filters to SAP response packets the MAX unit transmits. If the unit receives a 
SAP request packet, it applies output filters before transmitting the SAP response, and 
excludes services from or includes services in the response packet as specified by the output 
filter.
For detailed information about each parameter, see the MAX Reference.
Parameter
Specifies
Valid
Enable/disable an individual input or output filter.
Type
Whether an individual input or output filter includes the service 
specified by the Server Type parameter or excludes it.
In an input filter, the Type parameter specifies whether to include 
remote services of the specified type in the MAX unit’s SAP table or 
exclude them.
In an output filter, the Type parameter specifies whether to include 
advertisements for the specified service type in SAP response packets 
or to exclude them. 
Server Type
A hexadecimal number representing a type of NetWare service to be 
included or excluded as specified by the Type parameter. For example, 
the number for file services is 0004.
Server Name
Local or remote NetWare server’s name. If the server is on the local 
network, you might name it in an output filter, in which the Type 
parameter specifies whether or not to include advertisements for this 
server in SAP response packets. If the server is on the remote IPX 
network, you might name it in an input filter, in which the Type 
parameter specifies whether or not to include this server in the MAX 
unit’s SAP table.