Lucent Technologies 6000 User Manual
6-38
MAX 6000/3000 Network Configuration Guide
Configuring X.25
Always On/Dynamic ISDN (AO/DI)
Always On/Dynamic ISDN (AO/DI)
Configuring the Answer profile
To configure the Answer profile to allow support of AO/DI:
1
From the main Edit menu, select Ethernet > Answer profile.
2
Open the Encaps submenu.
3
Set MP to Yes.
4
Set PPP to Yes.
5
Close the Encaps submenu.
6
Open the PPP options submenu.
7
Set BACP=Yes.
8
Exit the profile and, at the exit prompt, select the exit and accept option.
Configuring a Connection profile to support AO/DI
Before you configure a Connection profile to support AO/DI, you must understand each of the
X.25 parameters related to the Connection profile.
X.25 parameters related to the Connection profile.
The following list displays the X.25 connection parameters whose descriptions appear
beginning on page 6-8.
beginning on page 6-8.
Ethernet
Connections
Connection profile
Encaps=X.25/PAD
Encaps Options
X25 Prof
X25 Reverse Charge
RPOA
CUG Index
NUI
Call Mode
Answer X.121 Addr
Remote X.121 Addr
Configuring a Connection profile
To configure a Connection profile to support AO/DI:
1
From the main Edit menu select Ethernet > Connections > any Connection profile.
2
Set Active to Yes.
3
Set Encaps to MP.
4
Open the Telco options submenu
5
Set Call Type to AO/DI.
6
From the Connection profile menu, open the Encaps options submenu.
7
Set BACP to Yes.
8
Set both Base Ch Cnt and Max Ch Cnt parameters to the maximum number of channels
allowed for the connection.
allowed for the connection.
9
Set InterfaceType to X.25.