Lucent Technologies 7820-0657-001 User Manual

Page of 34
Viewing configuration information
3-4
DSLPipe DSU (SDSL) User’s Guide
V35
Indicates 
OFF_line 
or 
ON_line
Data Bit Polarity
Indicates 
Norm
 (Normal) or 
Rev
 (Reverse). The default is 
Rev.
This means that the transmitter inverts the data polarity 
before sending data.
Sign/Magn Bit Seq
Indicates 
Norm
 (Normal) or 
Rev
 (Reverse). The default is 
Rev
. This means that the magnitude bit is followed by the sign 
bit.
Noise Margin
Shows the noise margin value (in dB). If the noise margin is 
less than -5dB, the SDSL line is terminated. 
Data Rate
Shows the current transmission rate
DSL ch Data 
Encode/Decode
Shows one of the following: 
NRZ
NRZI
FMO
FM1
, or 
Manchester
. The default is NRZ. This means that signal 
transmissions go from positive to negative without ever 
assuming a zero value (Non-Return to Zero).
V.35 ch Data 
Encode/Decode
Shows one of the following: 
NRZ
NRZI
FMO
FM1
, or 
Manchester
. The default is NRZ. This means that signal 
transmissions go from positive to negative without ever 
assuming a zero value (Non-Return to Zero).
DSL ch Rx CRC
Shows either 
Enable
 or
 Disable
. The default is 
Enable
This means that the receiver will check for CRC over the SDSL 
line. 
DSL ch Tx CRC
Shows either 
Enable
 or 
Disable
. The default is 
Enable
This means that the CRC is appended to the end of the frame 
when data is sent over the SDSL line
.
V.35 ch Rx CRC
Shows either 
Enable
 or
 Disable
. The default is 
Enable
This means that the receiver will check for CRC over the V.35 
line.
Table 3-1. Fields in the DSLPipe status window (Continued)
Fields
Description