Lucent Technologies Cajun M770 User Manual

Page of 72
66
Cajun M400 Manager User’s Guide
Clock Admin State
The administered clock synchronization state of the 
M-SPS module. Possible states are:
• enable - Clock synchronization is enabled on 
the device.
• disable, use Internal Clock - Clock 
synchronization is disabled on the M-SPS 
module. The M-SPS module uses its internal 
low accuracy (
±
20 ppm) oscillator.
Clock Status
The status of clock synchronization on the device. 
Possible statuses are:
• locked - The M-SPS module is using a clock 
which is locked to the input timing source.
• holdover - The M-SPS module is simulating a 
clock to which it was previously locked. This 
state will last until the clock source is fixed.
• free_running - The M-SPS module is using its 
±4.6 ppm oscillator to generate timing. This only 
occurs after a reset when there are no healthy 
timing sources available or when all four 
sources are configured with a priority of 0.
• internal - Clock synchronization is disabled and 
the M-SPS module is using its low accuracy 
(±20 ppm) internal oscillator to generate timing.
Configuration Symbol
For Module Configuration: The version of the 
module. The version is updated whenever there is a 
functional modification to the module.
For Agent Configuration: The version of the 
hardware and firmware of the agent.
Connected To
The DomainX to which the selected module is 
connected - DomainXL for the left DomainX and 
DomainXR for the right DomainX.
Current Source
The current source clock used for clock 
synchronization. Possible sources are:
• ATM A/B - An ATM port on the device.
• SYNC A/B - An external source connected to the 
front panel of the M-SPS.
• none - No recognizable clock source.
Field Name
Description