Lantronix 900-332 User Manual

Page of 80
Configuration Using DeviceInstaller 
3-8  
WiPort™ 
User 
Guide 
Packing 
Enable Packing 
Two firmware-selectable packing algorithms define how and 
when packets are sent to the network. The standard algorithm 
is optimized for applications in which the unit is used in a local 
environment, allowing for very small delays, while keeping the 
packet count low. The alternate packing algorithm optimizes 
the packet for the network and is especially useful in 
applications in a routed Wide Area Network (WAN). Adjusting 
parameters in this mode can economize the network data 
stream. 
Select True to enable packing on the WiPort. 
Idle Time 
Select the maximum time for inactivity between data bytes on 
the serial port.  The default time is 12 milliseconds. 
Match Byte 1 
Use to set the termination byte.  Set this value to 00 if not 
used. 
Match Byte 2 
Use to indicate the end of a series of data to be sent as one 
group. Set this value to 00 if specific functions are not needed. 
Match 2 Byte Sequence 
Used with Match Byte 1 and Match Byte 2 to indicate the 
end of a series of data to be sent as one group.  The 
sequence must occur sequentially to indicate to the WiPort 
end of the data packet. 
Send Frame Only 
After the detection of the byte sequence, indicates whether to 
send the data frame or the entire buffer (i.e. include the trailing 
bytes). Select True to send only the data frame. 
Send Trailing Bytes 
Select the number of bytes to send after the end-of-sequence 
characters. 
7.  To exit the Channel 1 and Channel 2 configurations, click OK
Email Configuration 
The unit sends an e-mail when a specific trigger event occurs. There are three 
separate triggers, based on any combination of the configurable pins (PIO) when 
selected as user I/O functions. Optionally, use a two-byte serial string to initiate a 
trigger. 
To configure the WiPort’s email settings: 
1.  From the Configure Device window for the WiPort unit, click the Advanced tab. 
2.  In the Email Notification section, enter the following fields: 
Domain Name 
Enter the Email server’s domain name. 
Mail Server 
Enter the IP address of the mail server. 
Recipients 
Click the “” box to open the Email Recipient Collection 
Editor window.  Click on an entry in the Members section and 
enter the email address in the Email Recipient Properties 
window.  Click OK when finished.