Lantronix 900-332 User Manual

Page of 80
Configuration Via Serial Mode or Telnet Port 
WiPort™ User Guide 
5-5 
Channel 1 and Channel 2 Configuration  
Select option 1 Channel 1  or 2 Channel 2 from the Change Setup menu to define 
how the serial port responds to network and serial communications
.
 The following 
sections describe the configurable parameters within the Channel configuration 
menu.
 
Figure 5-5.  Serial and Telnet Port Parameters  
Baudrate  
The unit and attached serial device, such as a modem, must agree on a speed or 
baud rate to use for the serial connection. Valid baud rates are 300, 600, 1200, 2400, 
4800, 9600 (default), 19200, 38400, 57600, 115200, 230400, 460800, or 921600. 
The current value is displayed in parentheses. 
Baudrate (9600) ? _ 
 
I/F (Interface) Mode  
The Interface (I/F) Mode is a bit-coded byte entered in hexadecimal notation. The 
current value is displayed in parentheses. 
I/F Mode (4C) ? _ 
The following table displays available I/F Mode options: 
Table 5-2.
 
Interface Mode Options 
I/F Mode Option  
 7   6  
5  
4  
3  
2  
1  
0  
RS-232C  
(1)
 
 
 
 
 
 
 
0  
0  
7 Bit  
 
 
 
 
1  
0  
 
 
8 Bit  
 
 
 
 
1  
1  
 
 
No 
Parity 
 
  0 0 
 
    
Even 
Parity 
 
  1 1 
 
    
Odd 
Parity 
 
  0 1 
 
    
1 stop bit  
0  
1  
 
 
 
 
 
 
2 stop bits
(1)
 
1  
1  
 
 
 
 
 
 
(1) 2 stop bits are implemented by the software. This might influence performance.