Navionics 87043_1 User Manual

Page of 54
28
E-Series Installation Manual
Radar cable (not supplied)
Having ensured that the radar scanner you are using is compatible with the E-Series 
Display (see “Compatibility” on page 9), the cable should be connected as follows:
Connecting to a Radome
If you are using a radome this can be powered through the display. Just run your cable 
and connect it to the radome and the display. 
If the existing cable is too short, please order from the following:
            
Connecting to an open array
If you are using an open array, this cannot be powered through the display. You will 
need to purchase a split pedestal cable:
...for new installations
            
            
Part No.
Cable length
Weight
Radome power output
E55065
15m
Heavy
2Kw or 4 Kw
E55066
25m
Heavy
2Kw or 4 Kw
E55067
10m
Light
2kw
E55068
15m
Light
2kw
Part No
Description
E55063
15m Split pedestal cable
E55064
25m Split pedestal cable
Split pedestal cable
To display
To power
To Open
Array Scanner
D7209-1
Note:  You should ensure that the distance (cable route) from the power supply to the
open array is kept to a minimum.