113
Installation
 Chapter 13: VSM-6804 Digital Composite Video Signal Monitor Module
LED Indicators
 Interface Switches 
LED
Indication
525 or 625 LED
On indicates that the module is operational 
and the incoming signal is properly 
detected.
Error LED
Steady On and Black Burst test signal at the 
analog output indicate the absence of 
incoming data.
Switch Setting
Function
Standard Select
In the Man position the user can force the 
output standard to the required mode (in 
case of an input signal mismatch the 
module gives the Error LED indication). If 
the user always operates in only one 
standard it is advisable to use the Man 
mode for faster lockup. In Auto mode the 
VSM-6804 determines and switches to the 
detected line standard.
Force
This is to select between 525 and 625 line 
standard modes and active only if Standard 
Select is in Man position.
525 Standard
This is to select between output standards 
NTSC and PALM. Since the incoming 
signal is component digital this selection is 
always made by the user even in the Auto 
mode.
Vertical Blanking
In the Pass mode the encoder is 
transparent in the vertical blanking. In the 
Blnk mode any luminance and 
chrominance data is substituted by black. 
(no setup in case of 525 signals.)
Vblank Chroma
In the Off position the chrominance 
content is removed from the signal in the 
vertical banking area, otherwise 
transparent.