Figure 39   Default setting of DIP switches
Description of DIP switch settings is given in the following table:
c
CAUTION:
It is recommended to select the DIP switch in this way: when connecting 
75-ohm cable, flip BIT1-8 to ON, and when connecting 120-ohm cable, flip 
BIT1-8 to OFF.
By default, all of the DIP switches are factory-configured to ON, that is, the 
impedance of E1 interface is 75-ohm.
Interface LEDs
The following figure illustrates the SIC-1VE1 panel.
Table 21   Description of DIP switch settings of SIC-ERRI/SIC-1E1-F
DIP Description 
Configuration of 
75-ohm impedance 
Configuration of 
120-ohm impedance 
1BIT 75-ohm/120-ohm 
selection switch 
ON OFF 
2BIT
ON OFF 
3BIT
ON OFF 
4BIT
ON OFF 
5BIT
ON OFF 
6BIT RxRing 
grounding 
mode selection 
switch 
OFF: RxRing is 
grounded via 
capacitance.
ON: RxRing is 
grounded directly. 
7BIT RxShield 
grounding 
mode selection 
switch 
- ON: 
RxShield 
is 
grounded.
OFF: RxShield is not 
grounded. 
8BIT SxShield 
grounding 
mode selection 
switch 
- OFF: 
RxShield 
is 
grounded via 
capacitance
ON: RxShield is 
grounded directly.