Sun Microsystems 4500/3 User Manual

Page of 82
16
Cluster Platform 4500/3 User’s Guide • July 2001
Cabling the System
The Cluster Platform 4500/3 is shipped with the servers, hubs, and each of the
arrays already connected in the cabinet. You should not need to cable the system.
Refer to
for servicing the cables.
This section describes how the Cluster Platform 4500/3 components are cabled when
shipped from the factory. The integrated platform provides FC-AL cables connected
to the on-board GBICs on the I/O board. Serial cables connect the Ethernet hub to
the management server and 10BASE-T ports on the disk arrays.
For specific cabling connections, refer to Appendix C.
*530-2834 is a manufacturing part number.
Caution –
Partner pairs are not supported at this time. Do not connect the
partner-pair loop cables.
TABLE 2-4
Cluster Platform Cables
Component
Part Number
Quantity
SCSI cable
530-2834*
4
DB-25/RJ-45 serial cable
2151A
2
Null Ethernet cable
3837A
2
F100 cable
9715A
6
Serial cable
9524A
1
RJ-45 Ethernet cable
1871A
4