Siemens V 4.0 User Manual

Page of 244
46
GINA V4.0 System Administrator Guide – September 2000
Configuration language
6.2 Configuration language
The configuration generator
config
reads a text file which describes the configuration of
the entire system in a T-ORB-specific language. This file contains the necessary informa-
tion on the network protocol, the transaction monitor, T-ORB, and the specialist application.
The elements of the language include keywords, literals, separators and comments. Blanks,
tabs, line feeds, form feeds and white spaces are ignored. The characters
//
introduce a
comment, the line feed character terminates it.
6.2.1
Statements
The configuration language contains a range of statements which are introduced by key-
words; these are explained below. The statements include numerous UTM parameters [31].
The statements may contain two different styles: uppercase letters only or lowercase letters
only.
❍ ❍ ●
ADMIN
The
ADMIN
statements on the
system level
apply to all hosts, if there is no
ADMIN
statement
with the same user ID in the
 HOST
statement.
The
ADMIN
statements on the
host level
apply accordingly to all applications, if there is no
ADMIN
 statement in the application.
The optional ADMIN statement has the following parameters:
user ID (
LETTER
)
password (
LETTER
)
Example
ADMIN ( "srv1", "srv1" )
ADDRESS
The
 ADDRESS
statement describes how the foreign
openUTM application is to be
addressed by the GINA application.
It has the following parameters:
name of the transaction code (
LETTER
)
name of the subroutine (
LETTER
)
Example
ADDRESS ( "VSVONREB", "MV1VON" )