Siemens V 4.0 User Manual
58
GINA V4.0 System Administrator Guide – September 2000
Configuration language
PORTADDRESSES
The
PORTADDRESSES
statement contains the port numbers for the
TNSX
entries. The state-
ment has the following parameters:
–
first port number
–
last port number
See the CMX documentation [7] for information on value ranges.
The difference between the start address and end address must be large enough for each
BCAMAPPL
entry on the host to have its own port number. The following rules apply when
calculating the number of
BCAMAPPL
entries of an application:
–
Each
CONNECT
statement creates two
BCAMAPPL
entries.
–
If the
BEST_BCAMAPPL
flag is set in the
APPLICATION
statement, a separate
BCAMAPPL
entry is generated for each
SESSION
statement of the application.
–
Without the
BEST_BCAMAPPL
flag, the number of
BCAMAPPL
entries generated corre-
sponds to the maximum number of
SESSION
entries specified between the current
server application and one of its partners.
❍ ❍ ●
PRIORITIES
The
PRIORITIES
statement has the following format:
PRIORITIES
{
SYNC_PRIORITY(RELATIVE | ABSOLUTE | EQUAL [,free_sync] )
{
PRIO(1 [,PGWT] )
PRIO(2 [,PGWT] )
PRIO(3 [,PGWT] )
PRIO(4 [,PGWT] )
PRIO(5 [,PGWT] )
PRIO(6 [,PGWT] )
PRIO(7 [,PGWT] )
}
ASYN_PRIORITY(RELATIVE | ABSOLUTE | EQUAL)
{
PRIO(1 [,TIMER] [,EVENT] [,CYCLIC] [,PGWT] )
PRIO(2 [,TIMER] [,EVENT] [,CYCLIC] [,PGWT] )
PRIO(3 [,TIMER] [,EVENT] [,CYCLIC] [,PGWT] )
PRIO(4 [,TIMER] [,EVENT] [,CYCLIC] [,PGWT] )
PRIO(5 [,TIMER] [,EVENT] [,CYCLIC] [,PGWT] )
PRIO(6 [,TIMER] [,EVENT] [,CYCLIC] [,PGWT] )