Siemens S223 User Manual

Page of 381
UMN:CLI                                                                                                                                                              User  Manual 
SURPASS hiD 6615 S223/S323 R1.5 
114                                                                         A50010-Y3-C150-2-7619 
7.1.9.4 Generic 
Alarm 
Severity 
To configure generic alarm severity, use the following command. 
Command Mode 
Description 
snmp alarm-severity fan-fail
  {critical | major | 
minor
 | warning | intermediate
Configures the priority of fan-fail alarm 
snmp alarm-severity cold-start
 {critical | major 
minor | warning | intermediate
Configures the priority of cold-start 
alarm 
snmp alarm-severity broadcast-over
  {critical | 
major
 | minor | warning | intermediate
Configures the priority of broadcast-
over alarm 
snmp alarm-severity cpu-load-over
  {critical | 
major
 | minor | warning | intermediate
Configures the priority of cpu-load-over 
alarm 
snmp alarm-severity dhcp-lease
  {critical | ma-
jor
 | minor | warning | intermediate
Configures the priority of DHCP-lease 
alarm 
snmp alarm-severity dhcp-illegal
  {critical | 
major
 | minor | warning | intermediate
Configures the priority of DHCP-illegal 
alarm 
snmp alarm-severity fan-remove
  {critical | 
major
 | minor | warning | intermediate
Configures the priority of fan-remove 
alarm 
snmp alarm-severity ipconflict
 {critical | major 
minor | warning | intermediate
Configures the priority of IP conflict 
alarm 
snmp alarm-severity memory-over
  {critical | 
major
 | minor | warning | intermediate
Configures the priority of memory-over 
alarm 
snmp alarm-severity mfgd-block
  {critical | 
major
 | minor | warning | intermediate
Configures the priority of MFGD-block 
alarm 
snmp alarm-severity port-link-down
  {critical | 
major
 | minor | warning | intermediate
Configures the priority of port-link-down 
alarm 
snmp alarm-severity port-remove
  {critical | 
major
 | minor | warning | intermediate
Configures the priority of port-remove 
alarm 
snmp alarm-severity port-thread-over
 {critical | 
major
 | minor | warning | intermediate
Configures the priority of port-thread-
over alarm. 
snmp alarm-severity power-fail
 {critical | major 
minor | warning | intermediate
Configures the priority of power-fail 
alarm 
snmp alarm-severity power-remove
  {critical | 
major
 | minor | warning | intermediate
Configures the priority of power-remove 
alarm 
snmp alarm-severity rmon-alarm-rising
  {criti-
cal
 | major | minor | warning | intermediate
Configures the priority of RMON-alarm-
rising alarm. 
snmp alarm-severity rmon-alarm-falling
  {criti-
cal
 | major | minor | warning | intermediate
Configures the priority of RMON-alarm-
falling alarm. 
snmp alarm-severity system-restart
  {critical | 
major
 | minor | warning | intermediate
Configures the priority of system-restart 
alarm. 
snmp alarm-severity module-remove
  {critical | 
major
 | minor | warning | intermediate
Configures the priority of module-
remove alarm. 
snmp alarm-severity temperature-high
 {critical 
major | minor | warning | intermediate
Global 
Configures the priority of temperature-
high alarm.