Siemens S223 User Manual

Page of 381
User Manual                                                                               UMN:CLI 
SURPASS hiD 6615 S223/S323 R1.5 
A50010-Y3-C150-2-7619                                                                         129 
7.4.2 RMON 
Alarm 
There are two ways to compare with the threshold: absolute comparison and delta com-
parison. 
 
Absolute Comparison
: Comparing sample data with the threshold at configured in-
 
terval, if the data is more than the threshold or less than it, alarm is occurred 
 
Delta Comparison
: Comparing difference between current data and the latest data 
 
with the threshold, if the data is more than the threshold or less than it, alarm is oc-
 curred. 
You need to open RMON Alarm Configuration mode first to configure RMON alarm. 
Command Mode 
Description 
rmon-alarm
 <1-65535> 
Global 
Opens RMON Alarm Configuration mode. 
1-65535: index number 
 
The following is an example of listing available commands on RMON-alarm Configuration 
mode. 
SWITCH(config)# rmon-alarm 
SWITCH(config-rmonalarm[1])# ? 
RMON alarm configuration commands: 
  active 
Activate  the  event 
  do 
To run exec commands in config mode 
  exit 
End current mode and down to previous mode 
  falling-event 
Associate the falling threshold with an existing RMON 
      
event 
  falling-threshold 
Define the falling threshold 
  help 
Description of the interactive help system 
  owner 
Assign the owner who define and is using the history 
   
resources 
  rising-event 
Associate the rising threshold with an existing RMON 
        
event 
  rising-threshold 
Define the rising threshold 
  sample-interval 
Specify the sampling interval for RMON alarm 
  sample-type 
Define the sampling type 
  sample-variable 
Define the MIB Object for sample variable 
  show 
Show running system information 
  startup-type 
Define startup alarm type (default : rising) 
  write 
Write running configuration to memory or terminal 
SWITCH(config-rmonalarm[1])# 
 
7.4.2.1 
Subject of RMON Alarm 
User needs to configure RMON alarm and identify subject using many kinds of data from 
alarm. To identify subject of alarm, use the following command. 
Command Mode 
Description 
owner
 NAME RMON 
Identifies subject using related data, enter the name 
(max. 32 characters).