Siemens S223 User Manual

Page of 381
User Manual                                                                               UMN:CLI 
SURPASS hiD 6615 S223/S323 R1.5 
A50010-Y3-C150-2-7619                                                                         137 
The following is an example of configuring syslog message to send all logs higher than 
notice to remote host 10.1.1.1 and configuring local1.info to transmit to console. 
SWITCH(config)# syslog output notice remote 10.1.1.1 
SWITCH(config)# syslog output priority local1 info console 
SWITCH(config)# show syslog 
System logger on running! 
info local 
volatile 
info local 
non-volatile 
notice remote 
10.1.1.1 
 
local1.info console 
SWITCH(config)# 
 
7.5.2 Facility 
Code 
You can set a facility code of the generated syslog message. This code make a syslog 
message distinguished from others, so network administrator can handle various syslog 
messages efficiently. 
To set a facility code, use the following command. 
Command Mode 
Description 
syslog local-code
 <0-7> 
Sets a facility code. 
no syslog local-code 
Global 
Deletes a specified facility code. 
 
The following is an example of configuring priority of all syslog messages which is trans-
mitted to remote host 10.1.1.1, as the facility code 0. 
SWITCH(config)# syslog output err remote 10.1.1.1 
SWITCH(config)# syslog local-code 0 
SWITCH(config)# show syslog 
System logger on running! 
info local 
volatile 
info local 
non-volatile 
err remote 
10.1.1.1 
 
local_code 0 
SWITCH(config)# 
 
7.5.3 Syslog 
Bind 
Address 
You can specify IP address to attach to the syslog message for its identity. To specify IP 
address for syslog identity, use the following command. 
Command Mode 
Description 
syslog
 bind-address A.B.C.D 
Specifies IP address for a syslog message identity. 
no syslog bind-address 
Global 
Deletes a specified binding IP address.